Function

SIRCO are manually or remotely operated multipolar load break switches.
As switch disconnector, they make and break under load conditions and provide safe isolation.
They are designed for heavy duty applications up to 415 VAC - AC 23. Supplied “tropicalized” as standard, they can be installed in any environment

Conformity to standards

IS IEC 60947-3

References

SIRCO direct operation is available in X versions

Item Type Rated current Number of poles Frame size Control operator Select
26K14006A Front operation 63 4 B2 Direct : B1,J1 / External : S2
26K14010A Front operation 100 4 B2 Direct : B1,J1 / External : S2
26K13012A Front operation 125 3 B3 Direct : B1,J1 / External : S2
26K14011A Front operation 125 4 B2 Direct : B1,J1 / External : S2
26K14012A Front operation 125 4 B3 Direct : B1,J1 / External : S2
26K13016A Front operation 160 3 B3 Direct : B1,J1 / External : S2
26K14016A Front operation 160 4 B3 Direct : B1,J1 / External : S2
26K13019A Front operation 200 3 B3 Direct : B1,J1 / External : S2
26K13020A Front operation 200 3 B4 Direct : B2, J1 / External : S2
26K14019A Front operation 200 4 B3 Direct : B1,J1 / External : S2
26K14020A Front operation 200 4 B4 Direct : B2, J1 / External : S2
26K13025A Front operation 250 3 B4 Direct : B2, J1 / External : S2
26K14025A Front operation 250 4 B4 Direct : B2, J1 / External : S2
26K13030A Front operation 315 3 B4 Direct : B2, J1 / External : S2
26K13031A Front operation 315 3 B5 Direct : B2, J1 / External : S2
26K14030A Front operation 315 4 B4 Direct : B2, J1 / External : S2
26K14031A Front operation 315 4 B5 Direct : B2, J1 / External : S2
26K13039A Front operation 400 3 B4 Direct : B2, J1 / External : S2
26K13040A Front operation 400 3 B5 Direct : B2, J1 / External : S2
26K14039A Front operation 400 4 B4 Direct : B2, J1 / External : S2
26K14040A Front operation 400 4 B5 Direct : B2, J1 / External : S2
26K13050A Front operation 500 3 B5 Direct : B2, J1 / External : S2
26K14050A Front operation 500 4 B5 Direct : B2, J1 / External : S2
26K13063A Front operation 630 3 B5 Direct : B2, J1 / External : S2
26K14063A Front operation 630 4 B5 Direct : B2, J1 / External : S2
26K13080A Front operation 800 3 B6 Direct : C2 / External : S4
26K14079A Front operation 800 4 B5 Direct : B2, J1 / External : S2
26K14080A Front operation 800 4 B6 Direct : C2 / External : S4
26K13100A Front operation 1000 3 B6 Direct : C2 / External : S4
26K14100A Front operation 1000 4 B6 Direct : C2 / External : S4
26K13079A Front operation 800 3 B5 Direct : B2, J1 / External : S2
26K13124A Front operation 1250 3 B6 Direct : C2 / External : S4
26K13125A Front operation 1250 3 B7 Direct : C2 / External : S4
26K14124A Front operation 1250 4 B6 Direct : C2 / External : S4
26K14125A Front operation 1250 4 B7 Direct : C2 / External : S4
26K13160A Front operation 1600 3 B7 Direct : C2 / External : S4
26K14160A Front operation 1600 4 B7 Direct : C2 / External : S4
26K13179A Front operation 1800 3 B7 Direct : C2 / External : S4
26K13180A Front operation 1800 3 B7 Direct : C2 / External : S4
26K14179A Front operation 1800 4 B7 Direct : C2 / External : S4
26K14180A Front operation 1800 4 B7 Direct : C2 / External : S4
26K13200A Front operation 2000 3 B8 Direct : C2 / External : S5, V2
26K14200A Front operation 2000 4 B8 Direct : C2 / External : S5, V2
26K13250A Front operation 2500 3 B8 Direct : C2 / External : S5, V2
26K14250A Front operation 2500 4 B8 Direct : C2 / External : S5, V2
26K13320A Front operation 3200 3 B8 Direct : C2 / External : S5, V2
26K14320A Front operation 3200 4 B8 Direct : C2 / External : S5, V2

Advantages

Reliability and performance

The double breaking per pole, achieved through its sliding bar contact system, is a proven design that offers very high durability and short-circuit withstand. Improved breaking performance with quick opening and rapid closure.

Safety of property

The position indicator is located directly on the sliding bar contact mechanism, ensuring it can be seen in all circumstances.
The use of glass fibre reinforced polyester gives the SIRCO both high mechanical and thermal resistance.

Simplicity

The standardisation of the SIRCO range and its wide choice of common accessories enable:
-Simple mounting.
-Reduced stock management and storage costs.

Easy to install

The outdoors ranges are easy to install thanks to:
- A good centre-to-centre distance (up to 120 mm).
- Connection up to 6 x 185 mm².
- Connection accessories which facilitate both flat and edgewise connections.

Applications

  • Industry - Power availability for industrial process

Resources & Documentation

Assistance

331F85EE-06C9-4809-9910-162B465D771A Created with sketchtool.

Looking for product documentation?

Access product catalogues, operating instructions, technical documents, CAD files,  and more.

F3AF315C-0799-42F2-AF18-B1B77756CAE4 Created with sketchtool.

Questions? We Can help !

Contact our technical support.