itys_007_008_a_pro_jpg

ITYS E

Affordable and reliable protection for sensitive IT and electrical applications
Single/single phase UPS from 1 to 10 kVA

The solution for

• Professional workstations
• Industrial automation
• Security systems
• Telecom systems
• Banking ATM systems

Advantages

Best electrical protection

• True online double conversion technology (VFI) assures high availability and total load protection.
• Constant output voltage and frequency regulation makes ITYS E compatible with different applications, operating environments and GenSets.
• Automatic bypass supplies the loads in the event of overloads or faults.

Robust and versatile

• Compact tower UPS system saves space in the operating environment.
• No particular configuration on first startup.
• Easy connections via IEC 320 sockets or terminals.
• Wide input voltage tolerance limits the switchovers to battery mode prolonging the battery life.
• Manual bypass for periodic or emergency maintenance.

 

  • Standard and option features

  • Technical Data

     

    Rear view connections

     

     

     

    ityse_064_a.jpg

     

     

    ityse_065_a.jpg

     

    ityse_066_b.jpg

     

    ityse_067_a.jpg

     

    1. USB serial port
    2. RS232 serial port
    3. Slot for optional boards
    4. Output sockets
    5. Output terminals
    6. Input protection
    7. Input socket
    8. External battery connection
    9. EPO (Emergency Power Off)
    10. Manual bypass
    11. Input circuit breaker

    1 kVA

    2 kVA

    3 kVA

    6-10 kVA

     

     

     

     

    Output connections

     

    iec_socket_320.jpg

    universal_socket.jpg

    indian_standard.jpg

     

    IEC socket 320 (C13)

    Universal socket

    Indian standard
    (BIS compliant)

     

     

     

     

    Technical data

     

      ITYS E - UPS
    Sn 1000 VA 2000 VA 3000 VA 6000 VA 10000 VA
    Pn 800 W 1600 W 2400 W 4800 W 8000 W
    Input
    Voltage 230 V (1ph) 160÷300 V up to 110 V @ 60% load
    Rated frequency 50/60 Hz
    Power factor 0.99
    Output
    Rated voltage 208 / 220 / 230 / 240 V
    Voltage tolerance ± 1%
    Rated frequency 50/60 Hz (46÷54 Hz / 56÷64 Hz) (in battery mode 50/60 ± 0.1 Hz)
    Overload Up to 130% for 1 minute
    Crest factor 3:1
    Connections
    IEC standard 3 x IEC 320 4 x IEC 320 4 x IEC 320 + terminals terminals
    Universal standard 2 sockets 2 sockets 2 sockets + terminals terminals
    Indian standard 3 sockets 4 sockets 4 sockets + terminals terminals
    Batteries
    Type sealed lead-acid maintenance free - expected life 3/5 years
    Back-up time @75% of rated VA load pf 0.7
    (Models with internal batteries)
    8 min 9 min
    Voltage (Models without batteries) 36 VDC 96 VDC 192 VDC 240 VDC
    Battery charger (Models without batteries) Setting up to 6 A
    Communication
    Interfaces RS232 - USB
    Local communication software Local View
    Efficiency
    Online mode up to 90 %
    Environment
    Ambient service temperature 0 °C to +40 °C (15 °C to 25 °C for maximum battery lifetime)
    Relative humidity 0 to 95% without condensation
    Maximum altitude 1000 m without derating
    Noise level at 1 m < 55 dBA < 65 dBA
    UPS CABINET (Models with internal batteries)
    Dimensions W x D x H 145 x 285 x 220 mm 145 x 400 x 220 mm 190 x 425 x 320 mm 190 x 370 x 640 mm 190 x 450 x 640 mm
    Weight  10 kg 17 kg 28 kg 60 kg 75 kg
    UPS CABINET (Models without batteries)
    Dimensions W x D x H 145 x 285 x 220 mm 145 x 400 x 220 mm 145 x 400 x 220 mm 190 x 370 x 320 mm 190 x 450 x 320 mm
    Weight  5 kg 7 kg 8 kg 12 kg 16 kg
    Degree of protection IP20
    Standards
    Safety EN 62040-1
    EMC EN 62040-2
    Product declaration CE
    BIS certification R-41030651 - -