Function

Complete and professional, NETYS RT is a single-phase rack-tower UPS ensuring protection and availability of IT infrastructure that meet both requirements of power reliability and installation flexibility.

Conformity to standards

IEC 62040-1
IEC 62040-2
IEC 62040-3
AS 62040.1.1
AS 62040.1.2
AS 62040.2
RCM (E2376)

Superior

Best in class & certified performance to optimise usage and Total Cost of Ownership.

Advantages

Simple to install

- No configuration necessary on first startup.
- Space and time saving ‘tower-to-rack’ conversion mode.
- Compact footprint (tower mode).
- High density rack enclosure saving valuable cabinet rack space.

High protection and availability

- Online double conversion technology with sinusoidal waveform, completely filters out all disturbances from / to the mains power supply and ensures maximum protection of the utility.
- Wide tolerance of the input voltage reduces switchovers to battery mode, prolonging battery life.
- Possibility of 1+1 parallel and redundant configuration to maximise the availability of critical utilities (up to 22 kVA).
- Hot-swap plug-in manual bypass.

Certified performance

- Performance tested and verified by independent laboratory.
- Full performance up to 40 °C without derating.

Easy to use

- Clear and uncluttered multilanguage LCD display.
- Wide range of communication protocols for integration into LAN networks or Building Management Systems.
- IoT ready device for access to connected services.
- Load segmentation function to prioritize loads and manage critical situations.

Extended and flexible back-up time

- Hot-swap modular battery extension (EBM) to meet all back-up time requirements, even after installation.
- Battery ageing detection function.
- Fast recharge - even for very long back-up time.
- Li-Ion battery technology-ready.

Applications

  • Building - Power availability for IT infrastructure

Technical data

Sn 5000VA 7000VA 11000VA
Pn 5000W 6000W 10000W
Architecture online double conversion VFI with input PFC and automatic bypass
Parallel redundant function 1+1 1+1 1+1

 

Input
Model 5000VA 7000VA 11000VA
Voltage  230V (1ph) 100÷280V; (175÷280V @100% load)
Frequency  40/70Hz (50/60Hz +/-10% Auto-Selectable)
Power factor/THDi  >0.99/<3%
Input socket terminals

 

Output
Model 5000VA 7000VA 11000VA
Voltage 230V (1ph) selectable 200/208/220/240V - 50 or 60Hz +/-2 % (+/-0.05Hz in battery mode)
Power factor 1 @ 5kVA 1 @ 6kVA 1 @ 10kVA
Efficiency (online mode) up to 95,5% online mode
Overload capability up to 105% continuously; 125% x 2min; 150% x 30sec
Output connections terminals

 

Battery
Model 5000VA 7000VA 11000VA
Standard autonomy (min)(1) 13 8 9
Voltage 192VDC 192VDC 240VDC
Recharge time <6h to recover 90% capacity

 

Communication
Model 5000VA 7000VA 11000VA
Mimic panel LCD with menu available in 10 languages
RS232 MODBUS protocol
USB port
WEB / SNMP (Ethernet RJ45 port) option option option
COMM slot
Dry contacts
EPO input
Parallel port

 

Standards
Model 5000VA 7000VA 11000VA
Safety IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2
EMC IEC/EN 62040-2, AS 62040.2
Performance IEC/EN 62040-3 (efficiency tested by an external independent body)
Product declaration CE, RCM (E2376)
BIS certification R-41189065 R-41189065 -

 

Environment
Model 5000VA 7000VA 11000VA
Operating ambient temperature from 0 °C to +40 °C (up to 45 °C (2), from 15 °C to 25 °C for best battery life)
Storage temperature range from -15°C to +55°C
Relative Humidity 5-95% non-condensing
Noise level (ISO 3746) <55dBA

 

Dimensions & weight
Model 5000VA 7000VA 11000VA
UPS size std (W x D x H) 178 x 565 x 440 mm 178 x 565 x 440 mm 220 x 650 x 440 mm
UPS size RACK 2U+2U 2U+2U 2U+2U
UPS weight std 11 + 39 kg 12 + 39 kg 17 + 67 kg
IP rating IP20

 

External Battery Module (EBM)
Model 5000VA 7000VA 11000VA
EBM size (W x D x H) 89 x 565 x 440 mm 131 x 650 x 440 mm 131 x 650 x 440 mm
EBM RACK 2U 2U 3U
EBM weight 39 kg 39 kg 67 kg

 

(1) @ 75% of nominal load PF 0.7.
(2) Conditions apply.

System

Electrical options

- UPS models with tropicalised (Conformal Coating) boards.
- Hot-swap battery extension modules.
- Hot-swap manual bypass.
- 1+1 parallel module (5000 - 11000 VA).

Communication

Standard communication features

- 1 slot for communication options.
- USB port for UPS management.
- MODBUS RTU (RS232).
- RS485 for Li-ion battery BMS.
- LOCAL VIEW software for local UPS monitoring and shutdown for Windows, Linux and MAC Osx.

Communication options

- Dry-contact card.
- NET VISION: professional WEB/SNMP, ethernet interface for UPS monitoring and remote automatic shutdown (MODBUS TCP).
- RT-VISION: WEB/SNMP interface for UPS monitoring and management.
- Environmental Monitoring Device (EMD).
- REMOTE VIEW PRO supervision software.

Resources & Documentation

Assistance

Looking for product documentation?

Access product catalogues, operating instructions, technical documents, CAD files,  and more.