Strong Points
Function
DELPHYS MP Elite+ is a high performing transformer based UPS designed to secure power supply for critical industrial applications up to 1200kVA in parallel. The isolation transformer installed on the inverter output ensures a complete galvanic isolation between DC circuit and load output.
Conformity to standards
IEC/EN 62040-1, IEC/EN 62040-2
AS 62040.1.1, AS 62040.1.2, AS 62040.2
CE
RCM (E2376)
Advantages
High quality power supply
- Permanent operation in VFI mode (online double conversion).
- Output voltage precision under all load conditions.
- High overload capability to withstand abnormal load conditions.
- A very high short-circuit current capacity which facilitates the selection of protective devices for selectivity in the downstream distribution.
- An isolation transformer installed on the inverter output to ensure complete galvanic isolation between DC circuit and load output. This insulation also provides a separation between the two inputs when they are supplied by different sources.
- Sinusoidal ThdU output voltage < 2 % with linear loads and < 4 % with non-linear loads.
High availability
- Field-proven technology.
- Fault-tolerant architecture with redundancy of basic functions, such as the ventilation system.
- Easy maintainability reduces MTTR thanks to pull-out sub-assemblies and front access all components.
- Accurate diagnostics guarantee power supply to the load.
- Cascade failure prevention for parallel systems.
- Mechanical & electrical robustness for industrial environments.
- Soft start capability (ramp up) of the IGBT inverter allows a good operation even with a genset.
- Specifically designed to be adapted to different industrial environment: high IP protection options, high peak current capability, long back up time…
Cost-effective equipment
The "clean" IGBT rectifier allows:
- a high efficiency,
- a high and constant input power factor,
- a low THDi.
These characteristics help to limit the dimensions of upstream network infrastructure.
- Possibility to create new neutral system without additional losses (extra transformer required on by-pass line only).
- High short-circuit capability simplifies downstream protective devices.
- High power density: its small footprint saves space on your premises.
- Mains connection of the rectifier requires only 3 cables (no neutral).
- Battery connection to UPS requires only 2 cables.
User-friendly operation
- A control panel with graphic display for more ergonomic operation.
- An array of "com-slot" plug-in communication interfaces, for upgrading your operating requirements evolution.
Simplified maintenance
- An advanced diagnostic system.
- A remote access device connected to the remote maintenance centre.
- Easy access to subassemblies and components, facilitating tests and reducing maintenance time (MTTR).
Applications
- Data center - Power availability for precision cooling
- Industry - Power availability for industrial process
Technical data
| Sn [kVA] | 60 | 80 | 100 | 120 | 160 | 200 |
| Pn [kW] | 54 | 72 | 90 | 108 | 144 | 180 |
| Input / output | 3/3 | |||||
| Parallel configuration | up to 6 units (distributed or centralised bypass) | |||||
| Input | ||||||
|---|---|---|---|---|---|---|
| Model | 60 | 80 | 100 | 120 | 160 | 200 |
| Rated voltage | 380 V - 400 V - 415 V(1) | |||||
| Voltage tolerance | 342 to 460 V(2) | |||||
| Rated frequency | 50/60 Hz | |||||
| Frequency tolerance | 45 to 65 Hz | |||||
| Power factor / THDI | 0.99 constant / 2.5 % without filter | |||||
| Output | ||||||
|---|---|---|---|---|---|---|
| Model | 60 | 80 | 100 | 120 | 160 | 200 |
| Rated voltage | 380 V - 400 V - 415 V (configurable)(1) | |||||
| Voltage tolerance | < 1 % (static load), ± 2 % in 5 ms (dynamic load conditions from 0 to 100 %) | |||||
| Rated frequency | 50/60 Hz | |||||
| Frequency tolerance | ± 0.2% | |||||
| Total output voltage distortion - linear load | ThdU <2% | |||||
| Total output voltage distortion - non-linear load | ThdU <4% | |||||
| Short-circuit current on inverter (100ms) | Up to 3.5 In | |||||
| Overload | 150 % for 1 minute, 125 % for 10 minutes(2) | |||||
| Crest factor | 3:1 | |||||
| Bypass | ||||||
|---|---|---|---|---|---|---|
| Model | 60 | 80 | 100 | 120 | 160 | 200 |
| Rated voltage | 380 V - 400 V - 415 V | |||||
| Voltage tolerance | ± 10% (selectable) | |||||
| Rated frequency | 50/60 Hz | |||||
| Frequency tolerance | ± 2% (configurable for GenSet compatibility) | |||||
| Short-circuit current on by-pass (20ms) | Up to 24 In | |||||
| Efficiency | ||||||
|---|---|---|---|---|---|---|
| Model | 60 | 80 | 100 | 120 | 160 | 200 |
| Online mode | 93,5% | |||||
| Eco Mode | 98% | |||||
| Environment | ||||||
|---|---|---|---|---|---|---|
| Model | 60 | 80 | 100 | 120 | 160 | 200 |
| Operating ambient temperature | from 0 °C up to +40 °C(2) (from 15 °C to 25 °C for maximum battery life) | |||||
| Relative humidity | 0% - 95% without condensation | |||||
| Maximum altitude | 1000 m without derating (max. 3000 m) | |||||
| Acoustic level at 1 m (ISO 3746) |
65 dBA | 67 dBA | ||||
| UPS cabinet | ||||||
|---|---|---|---|---|---|---|
| Model | 60 | 80 | 100 | 120 | 160 | 200 |
| Dimensions W x D x H | 1000 x 800 x 1930 mm | |||||
| Weight | 740 kg | 860 kg | 1020 kg | |||
| Degree of protection | IP20 (other IP as option) | |||||
| Colours | RAL 9006 | |||||
| Standards | ||||||
|---|---|---|---|---|---|---|
| Model | 60 | 80 | 100 | 120 | 160 | 200 |
| Safety | IEC/EN 62040-1, AS 62040.1.1, AS 62040.1.2 | |||||
| EMC | - | IEC/EN 62040-2, AS 62040.2 | ||||
| EMC | - | CE, RCM (E2376) | ||||
(1) Others on demand.
(2) Conditions apply.
System
Electrical options
Electrical options:
- EBS (Expert Battery System)(2).
- ACS synchronisation system for 2n architecture.
- Redundant electronic power supplies.
- Hot plug option (increase the power keeping the load supplied in double conversion).
- Long back up time rectifier.
Mechanical options:
- Reinforced IP protection degree.
- Dust filters.
- Fan redundancy with failure detection.
- Top entry connection.
- Reinforced IP protection up to IP52.
Communication
Standard communication features
- Dry-contact interface (configurable voltage-free contacts).
- 3 slots for communication options.
Communication options
- User-friendly touch-screen multilingual colorgraphic display.
- MODBUS RTU RS485 or MODBUS TCP.
- PROFIBUS / PROFINET gateway.
- BACnet/IP interface.
- NET VISION: professional WEB/SNMP Ethernet interface for secure UPS monitoring and remote automatic shutdown.
- REMOTE VIEW PRO supervision software.
- IoT gateway for Socomec cloud services and SoLive UPS mobile app.
- Additional Com-slot extension.
Socomec services
Socomec offers comprehensive support to optimise the performance and longevity of your equipment. 400 experts and 250 engineers are mobilised to offer a complete service, from commissioning to end-of-life management of your equipment.
Commissioning
Commissioning by the manufacturer is the guarantee of safe, reliable and operational equipment.
Platinum Warranty
Platinum Warranty improves standard factory coverage: contractual response times, priority hotline access and optional preventive maintenance.
Maintenance
Benefit from Socomec experts available on-site and remotely to guarantee the performance of your equipment and optimize its life cycle.
Training
Strengthen your skills with Socomec-certified training and gain autonomy, performance and confidence.
SoLink remote monitoring
Reduce your contingencies with 24/7 monitoring of your critical equipment by Socomec experts.
SoLive Pro performance monitoring
Simply and securely view real-time data from your SUNSYS energy storage systems.
SoLive remote monitoring
Keep control of your Socomec equipment with a free real-time monitoring mobile app.
SoData data monitoring
Easily access raw data from Socomec connected products on the cloud.
Remote troubleshooting
Our experts troubleshoot your UPS remotely via reliable, secure diagnostics.