Strong Points
Function
DELPHYS MX Elite+ is a Three-phase UPS with a embedded transformerbased inverter designed to provide a continued power supply for your most critical installations. The isolation transformer provides galvanic isolation between the power converters and the user output.
Conformity to standards
IEC 62040-1
IEC 62040-2
Advantages
The best protection for your load
- Permanent operation in VFI mode (online double conversion).
- Provide accurate output voltage under all load conditions.
- High short-circuit current capacity, which facilitates the selection of protection devices in downstream distribution.
Robust & resiliant design
- Isolation transformer embedded with the inverter to ensure complete electrical isolation between the DC circuit and the load output.
- Fault-tolerant architectures with essential functional redundancy.
- Rugged mechanical and electrical properties for industrial environments.
- Redundant LED display for consistent UPS control.
- Standard PCB tropicalisation
User-friendly
- 10-inch color touch screen.
- User friendly HMI.
- Communication upgradable.
High availability and cost-effective equipment
- IGBT rectifier with PFC controller : high efficiency, high and constant input power factor, low current harmonic content.
- These features help limit the size of the upstream network infrastructure.
- ECO Mode with 99% efficiency.
- Accurate diagnosis ensures the power supply of the load.
- Prevent cascading failures of parallel systems.
- Rectifier soft start function, prevents generators loadstep ensuring smooth operation.
- Specifically designed to be adapted to different industrial environments: higher IP protection capability, longer backup time.
- Field-proven technology.
- Easy maintainability reduces MTTR thanks to pull-out sub-assemblies and full front accessible components.
Applications
- Healthcare - Critical power for operating theatre
- Infrastructure & Transport - Power for railway signaling
- Industry - Power availability for industrial process
- Building - Power availability for life safety
- Building - Power availability for IT infrastructure
Technical data
Sn [kVA] | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Pn [kW] | 52 | 72 | 90 | 108 | 144 | 180 | 225 | 270 | 360 | 450 | 540 |
Input / Output | 3/3 | ||||||||||
Parallel configuration | up to 6 units |
Input | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Rated voltage | 380V - 400V - 415V | ||||||||||
Voltage tolerance | ±20%(1) | ||||||||||
Rated frequency | 50/60Hz | ||||||||||
Frequency tolerance | ±10% | ||||||||||
Power factor | ≥ 0.99 @ full load | ||||||||||
Current harmonic content (THDI) | ≤ 3% full load |
Output | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Rated voltage | 380V - 400V - 415V | ||||||||||
Voltage tolerance | ±1% | ||||||||||
Rated frequency | 50/60Hz | ||||||||||
Frequency tolerance | Self-Oscillation ±0.1% | ||||||||||
Total output voltage distortion - linear load | ≤1% | ||||||||||
Total output voltage distortion - non-linear load | ≤5% | ||||||||||
Overload | up to 150% for 1 minute, 125% for 10 minutes | ||||||||||
Crest factor | 3:1 | ||||||||||
Short circuit current | Up to 3.5In (100ms) |
Bypass | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Rated voltage | 380V - 400V - 415V | ||||||||||
Rated frequency | 50/60Hz | ||||||||||
Frequency tolerance | ±5% |
Efficiency | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Online mode | Up to 94% | ||||||||||
Eco mode | Up to 99% |
Environment | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Ambient operating temperature | from 0°C up to +40°C(1) | ||||||||||
Humidity | 0%-95% without condensation | ||||||||||
Maximum altitude | 1000m without derating | ||||||||||
Acoustic level (as per ISO 3746) | 71 dBA | 73 dBA | 75 dBA | 80 dBA |
UPS cabinet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
UPS dimensions W x D x H (mm) | 800 x 850 x 1900 | 1000 x 850 x 1900 | 1500 x 1000 x 1900 | 2200 x 1000 x 1900 | |||||||
Weight | 800 kg | 900 kg | 1000 kg | 1350 kg | 2000 kg | 2800 kg | 3000 kg | ||||
Standard protection rating | IP20 / IP21 (optional) | ||||||||||
Colours | RAL 9006 |
Compliance to standards | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | 60 | 80 | 100 | 120 | 160 | 200 | 250 | 300 | 400 | 500 | 600 |
Safety / EMC | IEC 62040-1, IEC 62040-2 |
(1) Conditions apply.
System
- Extended top outlet solution.
- Higher IP protection level.
Communication
- Full communication function, RS485, RS232 and other communication interfaces.
- Dry contact with 8 NO/NC contacts.
- NET VISION: professional WEB/SNMP Ethernet interface for secure UPS monitoring and remote automatic shutdown.
- REMOTE VIEW PRO supervision software.
- IoT gateway for Socomec cloud services and SoLive UPS mobile app.