Function

SIRCOVER provide open transition switching (I-0-II), on-load transfer between two sources for any low voltage power circuit, as well as safety isolation with double breaking per pole. In addition to source changeover function, they can as well be used for source inversion (e.g. to change the direction of a motor) or grounding/earthing. They are availlable in 3 or 4 poles.

Conformity to standards

IEC 60947-6-1
IEC 60947-3
GB/T 14048.11

References

SIRCOVER I-0-II with direct handle is available in 32 versions

Item Rated current [A] Number of poles Frame size Control operator Type Select
41K14006A 63 4 B2 Direct : B2,J1 Manual I-0-II
41K14010A 100 4 B2 Direct : B2,J1 / External : S2 Manual I-0-II
41K13013A 125 3 B3 Direct : B3,J2 / External : S2 Manual I-0-II
41G14013A 125 4 B3 Direct : B3,J2 / External : S2 Manual I-0-II
41K14011A 125 4 CD Direct : B2,J1 Manual I-0-II
41K13016A 160 3 B3 Direct : B3,J2 / External : S2 Manual I-0-II
41G14016A 160 4 B3 Direct : B3,J2 / External : S2 Manual I-0-II
41K13020A 200 3 B3 Direct : B3,J2 / External : S2 Manual I-0-II
41G14020A 200 4 B3 Direct : B3,J2 / External : S2 Manual I-0-II
41K13025A 250 3 B4 Direct : B3,J2 / External : S2 Manual I-0-II
41G14025A 250 4 B4 Direct : B3,J2 / External : S2 Manual I-0-II
41K13031A 315 3 B4 Direct : B3,J2 / External : S2 Manual I-0-II
41G14031A 315 4 B4 Direct : B3,J2 / External : S2 Manual I-0-II
41K13040A 400 3 B4 Direct : B3,J2 / External : S2 Manual I-0-II
41G14040A 400 4 B4 Direct : B3,J2 / External : S2 Manual I-0-II
41K13050A 500 3 B5 Direct : B3,J2 / External : S2 Manual I-0-II
41K13063A 630 3 B5 Direct : B3,J2 / External : S2 Manual I-0-II
41G14063A 630 4 B5 Direct : B3,J2 / External : S2 Manual I-0-II
41K13079A 800 3 B5 CD Direct : B3,J2 / External : S2 Manual I-0-II
41G14079A 800 4 B5 Direct : B3,J2 / External : S2 Manual I-0-II
41K13100A 1000 3 B6 Direct : C1,J3 / External : S4 Manual I-0-II
41K14100A 1000 4 B6 Direct : C1,J3 / External : S4 Manual I-0-II
41K13120A 1250 3 B6 Direct : C1,J3 / External : S4 Manual I-0-II
41K14120A 1250 4 B6 Direct : C1,J3 / External : S4 Manual I-0-II
41K13160A 1600 3 B7 Direct : C1,J3 / External : S4 Manual I-0-II
41K14160A 1600 4 B7 Direct : C1,J3 / External : S4 Manual I-0-II
41K13200A 2000 3 B8 Direct : C2,S5 / External : S5 Manual I-0-II
41K14200A 2000 4 B8 Direct : C2,S5 / External : S5 Manual I-0-II
41K13250A 2500 3 B8 Direct : C2,S5 / External : S5 Manual I-0-II
41K14250A 2500 4 B8 Direct : C2,S5 / External : S5 Manual I-0-II
41K13320A 3200 3 B8 Direct : C2,S5 / External : S5 Manual I-0-II
41K14320A 3200 4 B8 Direct : C2,S5 / External : S5 Manual I-0-II

Advantages

A complete range

The standard model I-0-II from 125 to 3200A.

Easy to connect

For ratings of 2000 to 3200 A, we offer copper bar connection pieces. This gives you the option of different connection methods: flat, edgewise with top or bottom bridging.

Stable positions

SIRCOVER devices have three stable positions, unaffected by voltage fluctuations and vibrations, protecting your loads from network disturbances.

On-load switching

With its AC-23 and AC-33 characteristics, tested according to standards IEC 60947-3 and IEC 60947-6-1, the SIRCOVER enables safe on-load switching for any type of load. With its on-load transfer capabilities, it is not necessary to isolate loads prior to transfer therefore the SIRCOVER offers an economical solution.

Environmental data

Sustainable advantages Robust design, using durable and stable materials to maximise product lifetime.
Tested beyond market standards to maximise product lifetime - even in severe operating environments.
Sustainable compliance REACH compliant - declaration available upon request
RoHS compliant
Sustainability Socomec
Designing with responsibility means delivering long-term value

"A company's performance is measured not only by its financial success, but also and above all by its positive impact on society and the environment. This vision guides our every action and decision, and anchors sustainable development at the heart of our strategy. This commitment is embodied in the ACT 360 program." 

Ivan STEYERT - SOCOMEC Group CEO

Documentation

  • PDF
    SIRCOVER - Manually operated transfer switching equipment
    Select
  • PDF
    SIRCOVER - Manual Transfer Switching Equipment from 125 to 3200 A
    Select
  • PDF
    Load break & Transfer switching - On-load isolation and source changeover applications
    Select

Assistance

Looking for product documentation?

Access product catalogues, operating instructions, technical documents, CAD files,  and more.

Questions? We Can help !

Contact our technical support.