U3Ryb25nIFBvaW50cw==

  • VGhlIHVsdGltYXRlIGFsbC1wdXJwb3NlIHBvd2VyIHF1YWxpdHkgbWV0ZXI=

  • UGx1ZyAmIHBsYXk=

  • RnVsbHkgY3VzdG9taXphYmxl

  • QWR2YW5jZWQgZmVhdHVyZXMq

  • QmVzdC1pbi1jbGFzcyBhY2N1cmFjeQ==

  • RWFzeSBkYXRhIG1hbmFnZW1lbnQ=

RnVuY3Rpb24=

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

Classification

UNSPSC 83101808
ETIM Class EC002301
IGCC 6042

Commerce

Description Power quality meter DIRIS A-100 RJ12 current sensor, 115-600 VAC power supply with Modbus communication protocols and RS485 communication ports, Solid-core, Split-core or Rogowski coils are compatible
Effective date 2023-06-01
Offer Life Cycle Code 40
Country of origin US

Environmental Sustainability

Climate change - Total - Cradle to Grave [kg CO₂ eq.] 279
Climate change - Total - Cradle to Gate [kg CO₂ eq.] 39
SVHC > 0.1 mass percentage? No
RoHS applicable? Yes

ETIM - Electrical characteristics

Accuracy class active energy according to IEC 62053-22 0.1S
Accuracy class reactive energy according to IEC 62053-23 Other
Pulse output Electrical
Sampling frequency [Hz] 9600
Number of voltage measurement inputs 4
Number of current measurement inputs 4
Voltage type (supply voltage) AC
Supply voltage AC 50 Hz [V] 115..600
Supply voltage AC 60 Hz [V] 115..600
Measuring range for frequency [Hz] 50..60
Max. current (Imax) [A] 10000
Display resolution (horizontal) [px] 350
Display resolution (vertical) [px] 160
Number of digital inputs 3
Number of digital outputs 1
Suitable for RJ plug No
Supporting protocol for IEC 61850 Ethernet No
Supporting protocol for OPC UA PubSub No
Supporting protocol for PROFIBUS No
Supporting protocol for Modbus Yes
Supporting protocol for PROFINET IO No
Supporting protocol for other bus systems No
With firmware signature Yes
With logging of security events (security event log) Yes
Web server with HTTPS transfer protocol No

ETIM - Mechanical characteristics

Mounting method Front mounting
Width [mm] 98.5
Height [mm] 98.5
Depth [mm] 108
Degree of protection (IP), front side Other

ETIM - Technical features

Display Graphic
Remote display No
With communication interface KNX No
Wth communication interface M-Bus No
With communication interface RS-485 Yes

Logistics

GTIN/EAN 3596033205446
Customs number 9030320000
Price unit PC
Weight of the packing unit [kg] 0,44
Length of the packing unit [m] 0,135
Width of the packing unit [m] 0,12
Depth of the packing unit [m] 0,11

Technical Characteristics

Height [mm] 98.5
Width [mm] 98.5
Depth [mm] 108
Weight [kg] 0.326
Application Monitoring
Communication ports RS485
Communication protocols Modbus RTU
Model A-100
Type RJ12

Documentation

  • PDF
    DIRIS A-100 _ A-200 Multi-function power and energy meter
    Select
  • PDF
    DIRIS A-100_A-200 Power quality meter
    Select
  • DIRIS A-100 RJ12 SENSORS RS485 CAD 48250600
  • PDF
    DIRIS A-100 _ A-200_PEP
    Select
  • PDF
    DIRIS A-x00_UL certificate
    Select
  • PDF
    DIRIS A-x00_CB certificate
    Select

References

DIRIS A-100 / A-200 is also available in 3 versions