Function

SIRCO are manually or remotely operated multipolar load break switches.
As switch disconnector, they make and break under load conditions and provide safe isolation.
They are designed for heavy duty applications up to 415 VAC - AC 23. Supplied “tropicalized” as standard, they can be installed in any environment

Conformity to standards

IS IEC 60947-3

References

SIRCO external operation is available in X versions

Item Type Rated current Number of poles Frame size Control operator Select
26K24006A Front operation 63 4 B2 Direct : B1,J1 / External : S2
26K24010A Front operation 100 4 B2 Direct : B1,J1 / External : S2
26K23012A Front operation 125 3 B3 Direct : B1,J1 / External : S2
26K24011A Front operation 125 4 B2 Direct : B1,J1 / External : S2
26K24012A Front operation 125 4 B3 Direct : B1,J1 / External : S2
26K23016A Front operation 160 3 B3 Direct : B1,J1 / External : S2
26K24016A Front operation 160 4 B3 Direct : B1,J1 / External : S2
26K23019A Front operation 200 3 B3 Direct : B1,J1 / External : S2
26K23020A Front operation 200 3 B4 Direct : B2, J1 / External : S2
26K24019A Front operation 200 4 B3 Direct : B1,J1 / External : S2
26K24020A Front operation 200 4 B4 Direct : B2, J1 / External : S2
26K23025A Front operation 250 3 B4 Direct : B2, J1 / External : S2
26K24025A Front operation 250 4 B4 Direct : B2, J1 / External : S2
26K23030A Front operation 315 3 B4 Direct : B2, J1 / External : S2
26K23031A Front operation 315 3 B5 Direct : B2, J1 / External : S2
26K23180A Front operation 315 3 B7 Direct : C2 / External : S4
26K24030A Front operation 315 4 B4 Direct : B2, J1 / External : S2
26K24031A Front operation 315 4 B5 Direct : B2, J1 / External : S2
26K23040A Front operation 400 3 B5 Direct : B2, J1 / External : S2
26K23039A Front operation 400 3 B4 CD Direct : B2, J1 / External : S2
26K24039A Front operation 400 4 B5 Direct : B2, J1 / External : S2
26K24040A Front operation 400 4 B5 Direct : B2, J1 / External : S2
26K23050A Front operation 500 3 B5 Direct : B2, J1 / External : S2
26K24050A Front operation 500 4 B5 Direct : B2, J1 / External : S2
26K23063A Front operation 630 3 B5 Direct : B2, J1 / External : S2
26K24063A Front operation 630 4 B5 Direct : B2, J1 / External : S2
26K23079A Front operation 800 3 B5 Direct : B2, J1 / External : S2
26K24079A Front operation 800 4 B5 Direct : B2, J1 / External : S2
26K24080A Front operation 800 4 B6 Direct : C2 / External : S4
26K23100A Front operation 1000 3 B6 Direct : C2 / External : S4
26K24100A Front operation 1000 4 B6 Direct : C2 / External : S4
26K23124A Front operation 1250 3 B6 Direct : C2 / External : S4
26K23080A Front operation 800 3 B6 Direct : C2 / External : S4
26K23125A Front operation 1250 3 B7 Direct : C2 / External : S4
26K24124A Front operation 1250 4 B6 Direct : C2 / External : S4
26K24125A Front operation 1250 4 B7 Direct : C2 / External : S4
26K24160A Front operation 1250 4 B7 Direct : C2 / External : S4
26K23160A Front operation 1600 3 B7 Direct : C2 / External : S4
26K24179A Front operation 1600 4 B7 Direct : C2 / External : S4
26K23179A Front operation 1800 3 B7 Direct : C2 / External : S4
26K23200A Front operation 1800 3 B8 Direct : C2 / External : S5, V2
26K24180A Front operation 1800 4 B7 Direct : C2 / External : S4
26K24200A Front operation 2000 4 B8 Direct : C2 / External : S5, V2
26K23250A Front operation 2500 3 B8 Direct : C2 / External : S5, V2
26K24250A Front operation 2500 4 B8 Direct : C2 / External : S5, V2
26K23320A Front operation 3200 3 B8 Direct : C2 / External : S5, V2
26K24320A Front operation 3200 4 B8 Direct : C2 / External : S5, V2

Advantages

Reliability and performance

The double breaking per pole, achieved through its sliding bar contact system, is a proven design that offers very high durability and short-circuit withstand. Improved breaking performance with quick opening and rapid closure.

Safety of property

The position indicator is located directly on the sliding bar contact mechanism, ensuring it can be seen in all circumstances.
The use of glass fibre reinforced polyester gives the SIRCO both high mechanical and thermal resistance.

Simplicity

The standardisation of the SIRCO range and its wide choice of common accessories enable:
-Simple mounting.
-Reduced stock management and storage costs.

Easy to install

The outdoors ranges are easy to install thanks to:
- A good centre-to-centre distance (up to 120 mm).
- Connection up to 6 x 185 mm².
- Connection accessories which facilitate both flat and edgewise connections.

Applications

  • Industry - Power availability for industrial process

Resources & Documentation

Assistance

331F85EE-06C9-4809-9910-162B465D771A Created with sketchtool.

Looking for product documentation?

Access product catalogues, operating instructions, technical documents, CAD files,  and more.

F3AF315C-0799-42F2-AF18-B1B77756CAE4 Created with sketchtool.

Questions? We Can help !

Contact our technical support.