U3Ryb25nIFBvaW50cw==

  • UmVsaWFiaWxpdHkgYW5kIHBlcmZvcm1hbmNl

  • U2FmZXR5IG9mIHByb3BlcnR5IGFuZCBwZXJzb25uZWw=

  • U2ltcGxpY2l0eQ==

  • IEVhc3kgdG8gaW5zdGFsbA==

RnVuY3Rpb24=

U0lSQ08gYXJlIG1hbnVhbGx5IG9wZXJhdGVkIGxvYWQgYnJlYWsgYW5kIGlzb2xhdGlvbiBzd2l0Y2hlcy4gVGhleSBtYWtlIGFuZCBicmVhayB1bmRlciBsb2FkIGNvbmRpdGlvbnMgYW5kIHByb3ZpZGUgc2FmZSBpc29sYXRpb24uIFNJUkNPIGFyZSBkZXNpZ25lZCBmb3IgNDE1IFZBQyBlbGVjdHJpY2FsIGNpcmN1aXRzLg==

Classification

UNSPSC 39122233
ETIM Class EC000216
IGCC 5290

Commerce

Description Manually operated Load break and isolation switch SIRCO INDIA frame B5 with 3 poles, 630A frontal external operation with handle type S2. Delivered with handle
Effective date 2016-06-14
Offer Life Cycle Code 40
Country of origin IN

ETIM - Electrical characteristics

Max. rated operation voltage Ue AC [V] 415
Rated operating voltage [V] 415..415
Rated permanent current Iu [A] 630
Rated permanent current at AC-23, 400 V [A] 630
Rated permanent current at AC-21, 400 V [A] 500
Rated short-time withstand current lcw [kA] 11
Rated operation power at AC-23, 400 V [kW] 375
Switching power at 400 V [kW] 375
Conditioned rated short-circuit current Iq [kA] 50
Number of poles 3

ETIM - Mechanical characteristics

Suitable for floor mounting No
Suitable for front mounting 4-hole No
Suitable for front mounting centre No
Suitable for distribution board installation No
Suitable for intermediate mounting Yes
Colour control element Other
Degree of protection (IP), front side IP20

ETIM - Technical features

Version as main switch Yes
Version as maintenance-/service switch Yes
Version as safety switch Yes
Version as emergency stop installation Yes
Version as reversing switch No
Number of switches 1
Motor drive optional No
Motor drive integrated No
Voltage release optional No
Device construction Built-in device fixed built-in technique
Type of control element Other
Interlockable Yes
Type of electrical connection of main circuit Bolt connection

Logistics

GTIN/EAN 3596032957896
Customs number 8536508000
Price unit PC
Weight of the packing unit [kg] 0.001

Norms

Conformity to standards IEC

Technical Characteristics

Control operator Direct : B2, J1 / External : S2
Number of poles 3
Rated current [A] 630
Type Front operation
Frame size B5

Documentation

  • PDF
    SIRCO - Load break and isolation switches for power distribution
    Select
  • PDF
    Load break & Transfer switching - On-load isolation and source changeover applications
    Select

References

SIRCO with external operation is available in 46 versions

Item Type Rated current [A] Number of poles Frame size Control operator Select
26K24006A Front operation 63 4 B2 Direct : B1,J1 / External : S2
26K24010A Front operation 100 4 B2 Direct : B1,J1 / External : S2
26K23012A Front operation 125 3 B3 Direct : B1,J1 / External : S2
26K24011A Front operation 125 4 B2 Direct : B1,J1 / External : S2
26K24012A Front operation 125 4 B3 Direct : B1,J1 / External : S2
26K23016A Front operation 160 3 B3 Direct : B1,J1 / External : S2
26K24016A Front operation 160 4 B3 Direct : B1,J1 / External : S2
26K23019A Front operation 200 3 B3 Direct : B1,J1 / External : S2
26K23020A Front operation 200 3 B4 Direct : B2, J1 / External : S2
26K24019A Front operation 200 4 B3 Direct : B1,J1 / External : S2
26K24020A Front operation 200 4 B4 Direct : B2, J1 / External : S2
26K23025A Front operation 250 3 B4 Direct : B2, J1 / External : S2
26K24025A Front operation 250 4 B4 Direct : B2, J1 / External : S2
26K23030A Front operation 315 3 B4 Direct : B2, J1 / External : S2
26K23031A Front operation 315 3 B5 Direct : B2, J1 / External : S2
26K23180A Front operation 315 3 B7 Direct : C2 / External : S4
26K24030A Front operation 315 4 B4 Direct : B2, J1 / External : S2
26K24031A Front operation 315 4 B5 Direct : B2, J1 / External : S2
26K23040A Front operation 400 3 B5 Direct : B2, J1 / External : S2
26K23039A Front operation 400 3 B4 CD Direct : B2, J1 / External : S2
26K24039A Front operation 400 4 B5 Direct : B2, J1 / External : S2
26K24040A Front operation 400 4 B5 Direct : B2, J1 / External : S2
26K23050A Front operation 500 3 B5 Direct : B2, J1 / External : S2
26K24050A Front operation 500 4 B5 Direct : B2, J1 / External : S2
26K24063A Front operation 630 4 B5 Direct : B2, J1 / External : S2
26K23079A Front operation 800 3 B5 Direct : B2, J1 / External : S2
26K24079A Front operation 800 4 B5 Direct : B2, J1 / External : S2
26K24080A Front operation 800 4 B6 Direct : C2 / External : S4
26K23100A Front operation 1000 3 B6 Direct : C2 / External : S4
26K24100A Front operation 1000 4 B6 Direct : C2 / External : S4
26K23124A Front operation 1250 3 B6 Direct : C2 / External : S4
26K23080A Front operation 800 3 B6 Direct : C2 / External : S4
26K23125A Front operation 1250 3 B7 Direct : C2 / External : S4
26K24124A Front operation 1250 4 B6 Direct : C2 / External : S4
26K24125A Front operation 1250 4 B7 Direct : C2 / External : S4
26K24160A Front operation 1250 4 B7 Direct : C2 / External : S4
26K23160A Front operation 1600 3 B7 Direct : C2 / External : S4
26K24179A Front operation 1600 4 B7 Direct : C2 / External : S4
26K23179A Front operation 1800 3 B7 Direct : C2 / External : S4
26K23200A Front operation 1800 3 B8 Direct : C2 / External : S5, V2
26K24180A Front operation 1800 4 B7 Direct : C2 / External : S4
26K24200A Front operation 2000 4 B8 Direct : C2 / External : S5, V2
26K23250A Front operation 2500 3 B8 Direct : C2 / External : S5, V2
26K24250A Front operation 2500 4 B8 Direct : C2 / External : S5, V2
26K23320A Front operation 3200 3 B8 Direct : C2 / External : S5, V2
26K24320A Front operation 3200 4 B8 Direct : C2 / External : S5, V2